Standardization Institute
of the Republic of North Macedonia
Search in catalogue
Buy ISO Standards

 

МКС EN 60079-13:2018

Home » Standardization » МКС EN 60079-13:2018
Status: Публикуван
Lang: English
Pages:
Published: 2018-02-28
National registry: 2/2018
Edition:
Related international standards
This standard is identical to:
EN 60079-13:2017
CLC/TC 31
This standard is identical to:
IEC 60079-13:2017
TC 31
Price: 0 MKD

This document at the moment can not be purchased over the Internet. Please contact the ISRSM info center.

Print

Macedonian title

Експлозивни атмосфери -Дел 13: Вид на заштита на опремата во просторија со надпритисок ,, p” и присилно вентилирана просторија ,,v".

English title

Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"

Macedonian scope

No information added.

English scope

IEC 60079-13:2017(E) gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment by pressurization or artificial ventilation or both as applicable when located in an explosive gas atmosphere or combustible dust atmosphere hazardous area with or without an internal source of a flammable gas or vapour. It also includes a room located in a non-hazardous area that has an internal source of release of a flammable gas or vapour. This document deals with rooms that are partially constructed in a manufacturer’s facility and intended to have the final installation completed on-site, as well as rooms that are constructed completely on-site. Rooms partially constructed in a manufacturer’s facility may include third-party verification. For rooms built on-site, this document can be used by plant operators as a guide for assessment of those facilities. This document represents a major technical revision of the requirements for equipment protection by pressurized room "p" and artificially ventilated room "v" and should be considered as introducing all new requirements. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision.  This edition includes the following significant technical changes with respect to the previous edition: - modification of the title of this document to include artificially ventilated room "v" in addition to pressurized room "p"; - addition of types of protection "pb", "pc", and "vc" and removal of types of protection "px", "py", "pz" and "pv"; - definition of the differences between pressurization and artificial ventilation types of protection; - removal of protection of rooms with an inert gas or a flammable gas from the scope of this document; - addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines. Additional information regarding the scope of this document can be found in Clause 1.

Technical committees


ICS



Directive

No information added.

National action



 Standard number
Lang
Status
Published
Pages
Price
 
Buy
English
Withdrawn 
2007-11-30 
24 p.
1096 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
English
Withdrawn 
2007-06-30 
78 p.
1814 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 0: General requirements
English
Withdrawn 
2009-12-30 
191 p.
2495 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 0: Equipment - General requirements
English
Published 
2012-12-30 
319 p.
2986 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 0: Equipment - General requirements
English
Published 
2015-02-28 
5 p.
492 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 0: Equipment - General requirements
English
Published 
2018-07-30 
296 p.
2986 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 0: Equipment - General requirements
English
Withdrawn 
2007-02-28 
71 p.
1814 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 1: Flameproof enclosures ''d''
English
Withdrawn 
2008-06-30 
148 p.
2230 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
English
Published 
2015-02-28 
189 p.
2495 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
English
Published 
2019-02-28 
p.
0 MKD 
PDF
Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
English
Withdrawn 
2007-02-28 
60 p.
1550 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 10: Classification of hazardous areas
English
Withdrawn 
2009-12-30 
135 p.
2230 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
English
Published 
2016-06-30 
227 p.
2646 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 10-1: Classification of areas - Explosive gas atmospheres
English
Withdrawn 
2009-12-30 
61 p.
1701 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 10-2: Classification of areas - Combustible dust atmospheres
English
Published 
2015-07-30 
56 p.
1550 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
English
Withdrawn 
2007-06-30 
233 p.
2646 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
English
Published 
2012-12-30 
289 p.
2986 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
English
Published 
2012-12-30 
39 p.
1323 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 13: Equipment protection by pressurized room "p"
English
Withdrawn 
2007-02-28 
65 p.
1701 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 14: Electrical installations in hazardous areas (other than mines)
English
Withdrawn 
2009-05-30 
196 p.
2495 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 14: Electrical installations design, selection and erection
English
Withdrawn 
2013-04-30 
1 p.
378 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 14: Electrical installations design, selection and erection
English
Published 
2016-11-30 
3 p.
416 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 14: Electrical installations design, selection and erection
English
Published 
2015-02-28 
282 p.
2986 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 14: Electrical installations design, selection and erection
English
Withdrawn 
2006-06-30 
84 p.
1966 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 15: Type of protection "n"
English
Withdrawn 
2007-02-28 
160 p.
2344 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 15: Construction, test and marking of type of protection "n" electrical apparatus
English
Published 
2012-12-30 
146 p.
2230 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
English
Withdrawn 
2007-02-28 
27 p.
1134 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 17: Inspection and maintenance of electrical installations in hazardous areas (other than mines)
English
Published 
2008-06-30 
74 p.
1814 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
Macedonian
Published 
2008-06-30 
45 p.
1399 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
English
Published 
2015-02-28 
282 p.
2986 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
English
Withdrawn 
2007-02-28 
35 p.
1248 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 18: Construction, test and marking of type of protection encapsulation "m" electrical apparatus
English
Published 
2008-10-30 
p.
0 MKD 
PDF
English
Withdrawn 
2010-05-30 
62 p.
1701 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 18: Equipment protection by encapsulation "m"
English
Published 
2015-07-30 
72 p.
1814 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 18: Equipment protection by encapsulation "m"
English
Published 
2018-02-28 
5 p.
492 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 18: Equipment protection by encapsulation "m"
English
Published 
2019-02-28 
2 p.
378 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 18: Equipment protection by encapsulation "m"
English
Withdrawn 
2008-06-30 
132 p.
2230 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
English
Published 
2012-12-30 
132 p.
2230 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
English
Published 
2015-07-30 
13 p.
756 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 19: Equipment repair, overhaul and reclamation
English
Withdrawn 
2007-02-28 
50 p.
1474 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 2: Pressurized enclosures "p"
English
Withdrawn 
2008-06-30 
111 p.
2117 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"
English
Published 
2015-04-30 
140 p.
2230 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"
English
Published 
2015-12-30 
8 p.
567 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 2: Equipment protection by pressurized enclosure "p"
English
Published 
2010-05-30 
152 p.
2344 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
English
Withdrawn 
2007-06-30 
127 p.
2230 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 25: Intrinsically safe systems
English
Published 
2012-12-30 
151 p.
2344 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 25: Intrinsically safe electrical systems
English
Published 
2015-02-28 
1 p.
378 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 25: Intrinsically safe electrical systems
English
Withdrawn 
2007-06-30 
20 p.
945 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 26: Construction, test and marking of Group II Category 1 G electrical apparatus
English
Withdrawn 
2008-06-30 
25 p.
1096 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 26: Equipment with equipment protection level (EPL) Ga
English
Published 
2015-02-28 
6 p.
492 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
English
Withdrawn 
2007-06-30 
17 p.
870 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 27: Fieldbus intrinsically safe concept (FISCO) and Fieldbus non-incendive concept (FNICO)
English
Published 
2009-05-30 
16 p.
794 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 27: Fieldbus intrinsically safe concept (FISCO)
English
Withdrawn 
2008-06-30 
39 p.
1323 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation
English
Published 
2015-12-30 
p.
0 MKD 
PDF
Explosive atmospheres - Part 28: Protection of equipment and transmission systems using optical radiation
English
Published 
2008-06-30 
100 p.
1966 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases
English
Published 
2017-02-28 
55 p.
1550 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 29-1: Gas detectors - Performance requirements of detectors for flammable gases
English
Withdrawn 
2008-06-30 
105 p.
2117 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
English
Published 
2015-07-30 
3 p.
416 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 29-2: Gas detectors - Selection, installation, use and maintenance of detectors for flammable gases and oxygen
English
Published 
2015-02-28 
p.
0 MKD 
PDF
Explosive atmospheres - Part 29-3: Gas detectors - Guidance on functional safety of fixed gas detection systems
English
Published 
2012-10-30 
75 p.
1814 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 29-4: Gas detectors - Performance requirements of open path detectors for flammable gases
English
Published 
2008-06-30 
53 p.
1550 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 30-1: Electrical resistance trace heating - General and testing requirements
English
Published 
2018-02-28 
p.
0 MKD 
PDF
Explosive atmospheres - Part 30-1: Electrical resistance trace heating - General and testing requirements
English
Published 
2008-06-30 
105 p.
2117 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 30-2: Electrical resistance trace heating - Application guide for design, installation and maintenance
English
Published 
2018-02-28 
p.
0 MKD 
PDF
Explosive atmospheres - Part 30-2: Electrical resistance trace heating - Application guide for design, installation and maintenance
English
Withdrawn 
2010-05-30 
21 p.
999 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
English
Published 
2015-02-28 
28 p.
1134 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t"
English
Published 
2015-07-30 
p.
0 MKD 
PDF
Explosive atmospheres - Part 32-2: Electrostatics hazards - Tests
English
Published 
2015-07-30 
79 p.
1814 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 33: Equipment protection by special protection ''s''
English
Published 
2012-12-30 
25 p.
1096 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion
English
Published 
2012-12-30 
38 p.
1323 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 35-1: Caplights for use in mines susceptible to firedamp - General requirements - Construction and testing in relation to the risk of explosion
English
Published 
2012-12-30 
25 p.
1096 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 35-2: Caplights for use in mines susceptible to firedamp - Performance and other safety-related matters
English
Withdrawn 
2008-06-30 
43 p.
1399 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
English
Published 
2015-07-30 
41 p.
1399 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
English
Withdrawn 
2008-06-30 
31 p.
1210 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 6: Equipment protection by oil immersion "o"
English
Published 
2016-06-30 
52 p.
1550 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
English
Withdrawn 
2006-06-30 
69 p.
1701 MKD 
PDF
BuyBuy
Electrical apparatus for explosive gas atmospheres - Part 7: Increased safety "e"
English
Withdrawn 
2007-06-30 
160 p.
2344 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
English
Published 
2018-02-28 
p.
0 MKD 
PDF
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
English
Published 
2016-06-30 
247 p.
2797 MKD 
PDF
BuyBuy
Explosive atmospheres - Part 7: Equipment protection by increased safety "e"